Lifeboats, Rescue boats & Davits - on board
Alexander Ryan's highly skilled technicians have all the knowledge required in order to efficiently inspect lifeboats, rescue boats and davits.
The Lifeboats, Rescue boats & Davits - on board inspection includes:
- Functional test of lifeboat and davit. Inspection of all components of lifeboat, dismount of the braking gear/winch assembly, davit components, inspection of the engine, the hooks and the connections
- Functional test of lifeboat and davit. Inspection of all components of lifeboat, dismount of the braking gear, inspection of the engine, the hooks and the connections. Load test with 110% load
- Functional test of lifeboat and davit. Inspection of all components of lifeboat, dismount of the braking gear, inspection of the engine, the hooks and the connections. Load test with 110% load
- Recharge of 45 Liter breathing air cylinder
- Examination of satisfactory condition and operation of the Free fall lifeboat/davit/winch and its systems. Operational test of the release function
- Complete examination of the condition and operation of the Free Fall lifeboat/davit/winch and its systems. Lifeboat On-load release test with 1.1 x SWL, winch Dynamic load test with 1.1 x SWL. Operational test of the release function
- Check for condition and operation of limit switches, gear, brakes, wire ropes
- Examination and function testing of satisfactory hook operation per regulations
- Lifeboat Air cylinder hydrotesting that includes dismounting, mounting, hydrotest, valve service
- Lifeboat Air Cylinder Inspection
- Third party inspection
- Contracted third party to carry out NDT testing
- Engineering department fee
- Brake pads replaced when worn past OEM recommendations or damaged linings
- Third party charges for repairs to manifold
- Lifeboat five year inspection and load test
- Lifeboat 5 yearly on load Hook Testing
Image | Code | Description |
---|---|---|
72788 | Annual Inspection of Lifeboat | |
72789 | Annual Inspection of Rescue Boat | |
72790 | Lifeboat Five year Inspection and load test (up to 35 prs) | |
72791 | Lifeboat Five year Inspection and load test ( 35-100 prs) | |
72792 | 5-year Inspection of Rescue Boat | |
72845 | Refilling of Lifeboat/ Rescue Boat Air Cylinder | |
72882 | Annual inspection of Free Fall Lifeboats | |
72883 | 5-year Inspection of Free Fall Lifeboat | |
72890 | Annual inspection of engine room/provision crane | |
72891 | 5-year inspection of engine room/provision crane | |
72905 | Lifeboat Repair and Additional Spares | |
72924 | Annual Inspection of LALIZAS Release Hook | |
72952 | Hydrotest of Lifeboat/ Rescue Boat Air Cylinder | |
73178 | Replacement of Lifeboat Davit Accumulators | |
73179 | Annual Inspection of Lifeboat/ Rescue Boat Air Cylinder | |
73182 | ARMS Lifeboat, Third Party Inspection | |
73187 | ARMS Lifeboat,Non Destructive Test,Magnetic Particle Inspection | |
73188 | ARMS Lifeboat, Engineering Fee | |
73562 | Rescue Boat`s Davit Annual Inspection | |
73563 | Rescue Boat`s Davit 5-year Inspection | |
73564 | Free Fall Lifeboat`s Davit Annual Inspection | |
73565 | Free Fall Lifeboat`s Davit 5-year Inspection | |
73566 | Lifeboat`s Davit Annual Inspection | |
73567 | Lifeboat`s Davit 5-year Inspection | |
73568 | Replacement of Lifeboat Davit`s Steel Wire Ropes | |
73569 | Replacement of Rescue Boat Davit`s Steel Wire Ropes | |
73570 | Replacement of Lifeboats Remote Activation Steel Wire Rope | |
73571 | Release Hook Inspection - by service | |
73572 | Replacement of Winch`s Brake Pads | |
73585 | ARMS Lifeboat, Manifold Repairs | |
73622 | Lifeboat Five Year Inspection and Load Test (100-300 prs) | |
73623 | ARMS Lifeboat 5 Yearly on load Hook Testing | |
75514 | 5-year Inspection of LALIZAS Release Hook |